Technical Specification:
♦ Tube power: 30W
♦ Number of tubes: 2
♦ Applicable static area: 30m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 100VA
♦ UV wavelength: Ozone free 253.7nm or Ozone 185nm
♦ Irradiance: 214uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ During the sterilization, if a person or an animal breaks into the room, the lamp will be alarmed and off, automatically open left.
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
Model:FY-55DSI
Technical Specification:
♦ Tube power: Philip UV lamp 55W
♦ Number of tubes: 2
♦ Applicable static area: 60m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 87VA
♦ UV wavelength: Ozone free 253.7nm
♦ Irradiance: 297uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ During the sterilization, if a person or an animal breaks into the room, the lamp will be alarmed and off, automatically open left.
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
Model:FY-30DS
Technical Specification:
♦ Tube power: 30W
♦ Number of tubes: 2
♦ Applicable static area: 30m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 100VA
♦ UV wavelength: Ozone free 253.7nm or Ozone 185nm
♦ Irradiance: 214uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
Model:FY-55DS
Technical Specification:
♦ Tube power: Philip UV lamp 55W
♦ Number of tubes: 2
♦ Applicable static area: 60m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 87VA
♦ UV wavelength: Ozone free 253.7nm
♦ Irradiance: 297uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
wooden box:116*30*43/1pcs/17kg
paper box:112*25*34/1pcs/10kg
Model:FY-30DSI
Technical Specification:
♦ Tube power: 30W
♦ Number of tubes: 2
♦ Applicable static area: 30m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 100VA
♦ UV wavelength: Ozone free 253.7nm or Ozone 185nm
♦ Irradiance: 214uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ During the sterilization, if a person or an animal breaks into the room, the lamp will be alarmed and off, automatically open left.
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
Model:FY-55DSI
Technical Specification:
♦ Tube power: Philip UV lamp 55W
♦ Number of tubes: 2
♦ Applicable static area: 60m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 87VA
♦ UV wavelength: Ozone free 253.7nm
♦ Irradiance: 297uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ During the sterilization, if a person or an animal breaks into the room, the lamp will be alarmed and off, automatically open left.
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
Model:FY-30DS
Technical Specification:
♦ Tube power: 30W
♦ Number of tubes: 2
♦ Applicable static area: 30m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 100VA
♦ UV wavelength: Ozone free 253.7nm or Ozone 185nm
♦ Irradiance: 214uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
Model:FY-55DS
Technical Specification:
♦ Tube power: Philip UV lamp 55W
♦ Number of tubes: 2
♦ Applicable static area: 60m2
♦ Voltage: 110V±10% or 220V±10%, Frequency: 50Hz±10%
♦ Input power: 87VA
♦ UV wavelength: Ozone free 253.7nm
♦ Irradiance: 297uw/cm2
♦ It is movable and foldable, the tube could be concealed inside, and adjusted to various angles: 30°,60°,90°,135°, 180°.
♦ It is equipped with a timer equipment with the time limitation of 15,30,60,90min
♦ Certificate:CE ROHS FCC ISO EPA
♦ Effect:Killing 100% Bacterium virus
wooden box:116*30*43/1pcs/17kg
paper box:112*25*34/1pcs/10kg