Availability: | |
---|---|
Quantity: | |
MDTHYQ1_0362
MDT
MDTHYQ1_0362
Features
●Instant exhaust reduces the time of preparation.
●The 0.1ml/ h adjustable high-precision infusion ensures infusion safety.
●Soft medicine bag design reduces medical waste.
Capacity
●100ml/ 150ml/ 200ml/ 275ml/ 350ml
Alarm function
1. Limiting alarm
2. Mechanical failure
3. Battery under-voltage
4. Pipeline jam
5. Assembly not in place or falling off
6. Infusion complete
Technical specification
Specification | Explanation |
Range of application | The product is used for pain caused by a variety of causes and patients who require continuous or intermittent injection of medication |
Administration route | Intravenous, epidural |
Administration mode | 1. Continuous Basal Infusion(CBI) 2. Patient-Controlled Analgesia(PCA) 3. Continuous Basal Infusion+Patient-Controlled Analgesia(CBA+PCA) |
Working power | DC6v (Four No.7 dry batteries) |
Permissible deviation in dosing accuracy | Set value (±10%) |
Standard capacity | 100ml/ 150ml/ 200ml/ 275ml/ 350ml |
Set dosing parameters | 000ml-999ml |
Continuous dosing (ml/ h) | 0-50( 0-10, increment by 0.1; 10-50, increment by 1) |
Additional dosing (ml/ time) | 0-6 (increment by 0.1) 7.0, 8.0, 9.0, 10 |
Time-locked interval (min) | 5-90, increment by 1 |
Features
●Instant exhaust reduces the time of preparation.
●The 0.1ml/ h adjustable high-precision infusion ensures infusion safety.
●Soft medicine bag design reduces medical waste.
Capacity
●100ml/ 150ml/ 200ml/ 275ml/ 350ml
Alarm function
1. Limiting alarm
2. Mechanical failure
3. Battery under-voltage
4. Pipeline jam
5. Assembly not in place or falling off
6. Infusion complete
Technical specification
Specification | Explanation |
Range of application | The product is used for pain caused by a variety of causes and patients who require continuous or intermittent injection of medication |
Administration route | Intravenous, epidural |
Administration mode | 1. Continuous Basal Infusion(CBI) 2. Patient-Controlled Analgesia(PCA) 3. Continuous Basal Infusion+Patient-Controlled Analgesia(CBA+PCA) |
Working power | DC6v (Four No.7 dry batteries) |
Permissible deviation in dosing accuracy | Set value (±10%) |
Standard capacity | 100ml/ 150ml/ 200ml/ 275ml/ 350ml |
Set dosing parameters | 000ml-999ml |
Continuous dosing (ml/ h) | 0-50( 0-10, increment by 0.1; 10-50, increment by 1) |
Additional dosing (ml/ time) | 0-6 (increment by 0.1) 7.0, 8.0, 9.0, 10 |
Time-locked interval (min) | 5-90, increment by 1 |